G6K
Surface Mounting Relay
Surface Mounting Relay with the World’s
Smallest Mounting Area
• Subminiature model as small as 5.2 (H) × 6.5 (W) × 10 (L) mm is ideal for
high-density mounting (G6K(U)-2F(-Y)).
• Low profile of 5.2 mm improves mounting efficiency (G6K(U)-2F(-Y)).
• Light weight of 0.7 g contributes to higher speed mounting.
• Surface mounting terminal models incorporate a unique terminal structure with
high infrared irradiation efficiency which allows the terminal temperature to rise
easily when mounting the IRS, thus ensuring excellent soldering.
• Ensures a dielectric strength of 1,500 VAC and conforms to FCC Part 68 (i.e.,
withstanding an impulse withstand voltage of 1,500 V for 10 × 160 μs).
• -Y models offer an impulse withstand voltage of 2,500 V for 2 × 10 μs (conforms
to Telcordia specifications) by optimizing the distance between coil and contacts.
• Standard model conforms to UL/CSA standards, certified by BSI (EN62368-1).
• Models available with a 2.54-mm terminal pitch.
• Rated carry current: 2A.
RoHS Compliant
■Model Number Legend
G
6
K
G 6 K@ -@ @ -@
1 2 3 4
1. Relay function
None : Single-side stable model
U : Single-winding latching model
2. Number of contact poles/Contact form
2 : 2-pole/DPDT (2c)
3. Terminal Shape
F : Outside-L surface mounting terminals
G : Inside-L surface mounting terminals
P : PCB terminals
4. Terminal Arrangement - Impulse withstand voltage
None :Terminal Arrangement
2.54 mm pitch
Impulse withstand voltage Between coil and contacts (1.5 kV for 10 × 160 μs)
Y :Terminal Arrangement
Between Coil-Contact Terminal 3.2 mm
Between Contact Terminal 2.2 mm pitch
Impulse withstand voltage Between coil and contacts
(Conforms to Telcordia specifications: 2.5 kV for 2 × 10 μs, 1.5kV for 10 × 160 μs)
■Application Examples
•
•
•
•
•
•
•
•
Telecommunication equipment
Office automation machines
Test and measurement equipment
Building automation equipment
Security equipment
Industrial equipment
Amusement equipment
Home appliances
1
G6K
Surface Mounting Relay
■Ordering Information
●Surface Mounting Terminal Standard Models
Packing
Enclosure
rating
Relay
Function
Contact form
Single-side
stable
Fully sealed
DPDT (2c)
G
6
K
Singlewinding
latching
Tube Packing
Rated coil
Minimum
voltage
packing unit
3 VDC
4.5 VDC
G6K-2F
5 VDC
12 VDC
24 VDC
3 VDC
Highly insulated 4.5 VDC
G6K-2F-Y
5 VDC
12 VDC
24 VDC
3 VDC
4.5 VDC
G6K-2G
5 VDC
12 VDC
24 VDC
50 pcs/tube
3 VDC
Highly insulated 4.5 VDC
G6K-2G-Y
5 VDC
12 VDC
24 VDC
3 VDC
Highly insulated 4.5 VDC
5 VDC
G6KU-2F-Y
12 VDC
24 VDC
3 VDC
Highly insulated 4.5 VDC
G6KU-2G-Y
5 VDC
12 VDC
24 VDC
Model
Model
G6K-2F-TR
Highly insulated
G6K-2F-Y-TR
G6K-2G-TR
Highly insulated
G6K-2G-Y-TR
Highly insulated
G6KU-2F-Y-TR
Highly insulated
G6KU-2G-Y-TR
Tape Packing
Rated coil
Minimum
voltage
packing unit
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
900 pcs/reel
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
●PCB Terminal Standard Models
Enclosure rating
Relay Function
Contact form
Model
Rated coil
voltage
Minimum
packing unit
3 VDC
4.5 VDC
G6K-2P
5 VDC
12 VDC
24 VDC
Single-side stable
Fully sealed
3 VDC
DPDT (2c)
Highly insulated
G6K-2P-Y
4.5 VDC
5 VDC
50 pcs/tube
12 VDC
24 VDC
3 VDC
Single-winding
latching
Highly insulated
G6KU-2P-Y
4.5 VDC
5 VDC
12 VDC
24 VDC
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G6K-2F DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Note 2. When ordering tape packing, add -TR" to the model number.
Be sure since -TR" is not part of the relay model number, it is not marked on the relay case.
When ordering tape packing, minimum order unit is 2 reels (900 pcs ✕ 2 = 1,800 pcs).
Note 3. Surface mounting terminal (SMT) standard models are shipped in moisture-proof package.
PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package.
2
Minimum ordering unit
(tape packing)
1,800 pcs/2 reels
G6K
Surface Mounting Relay
■Ratings
Coil: Single-side Stable Models
Item
Rated voltage
Rated
current
(mA)
Contacts
Must operate Must release Max. voltage
Coil
Power
(V)
resistance voltage (V) voltage (V)
consumption
(Ω)
(mW)
% of rated voltage
3 VDC
33.0
91
4.5 VDC
23.2
194
5 VDC
21.1
237
12 VDC
9.1
1,315
24 VDC
4.6
5,220
80% max.
10% min.
150%
Item
Load
Contact type
Approx.
100
Resistive load
Bifurcated crossbar
Contact material
Ag (Au-Alloy contact)
Rated load
0.3 A at 125 VAC,
1 A at 30 VDC
Rated carry current
2A
Max. switching voltage 125 VAC, 60 VDC
Max. switching current
1A
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance
of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Coil: Single-winding Latching Models (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y)
Item
Rated voltage
Rated
current
(mA)
Must operate Must release Max. voltage
Coil
Power
(V)
resistance voltage (V) voltage (V)
consumption
(Ω)
(mW)
% of rated voltage
3 VDC
33.0
91
4.5 VDC
23.2
194
5 VDC
21.1
237
12 VDC
9.1
1,315
24 VDC
4.6
5,220
75% max.
75% max.
150%
Approx.
100
G
6
K
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance
of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
■Characteristics
Relay Function
Item
Single-side stable models
Contact resistance *1
100 mΩ max.
Operating (set) time
3 ms max.
Release (reset) time
3 ms max.
−
Minimum set/reset signal width
Insulation resistance *2
Dielectric
strength
Impulse
withstand
voltage
Single-winding latching models
G6K-2F, G6K-2G, G6K-2PG6K-2F-Y, G6K-2G-Y, G6K-2P-YG6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y
10 ms
1,000 MΩ min. (at 500 VDC)
Between coil and
contacts
1,500 VAC, 50/60 Hz for 1 min
Between contacts of
different polarity
1,000 VAC, 50/60 Hz for 1 min
Between contacts of
the same polarity
750 VAC, 50/60 Hz for 1 min
Between coil and
contacts
1,500 V (10 × 160 μs)
2,500 V (2 × 10 μs), 1,500 V (10 × 160 μs)
Between contacts of
different polarity
1,500 V (10 × 160 μs)
Between contacts of
the same polarity
Vibration
resistance
Destruction
10-55-10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2
Malfunction
10-55-10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2
Shock
resistance
Destruction
1,000 m/s2
Durability
Malfunction
750 m/s2
Mechanical
50,000,000 operations min. (at 36,000 operations/hour)
Electrical
100,000 operations min. (with a rated load at 1,800 operations/hour)
10 μA at 10 mVDC
Failure rate (P level) *3
Ambient operating temperature
-40 to 70°C (with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1
VDC with a voltage-drop method.
*2. The insulation resistance was measured with a 500 VDC
megohmmeter applied to the same parts as those used for
checking the dielectric strength.
Approx. 0.7 g
*3.
This value was measured at a switching frequency of 120
operations/min and the criterion of contact resistance is
50 Ω. This value may vary depending on the switching
frequency
and
operating
environment.
Always
double-check relay suitability under actual operating
conditions.
3
G6K
Surface Mounting Relay
■Engineering Data
10
●Ambient Temperature vs.
Maximum Coil Voltage
1,000
7
5
3
1
0.7
500
300
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
100
50
5
3
1
0
300 500 700 1,000
0.2
0.4
50
0.6
●Ambient Temperature vs. Carry
Current
2.0
1.6
1.2
−20
0
20
40
60
80 100
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
●Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
On the basis of rated voltage (%)
2.4
0
−40
0.8
1
1.2
Switching current (A)
●Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
100
On the basis of rated voltage (%)
50 70 100
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Switching voltage (V)
Carry current (A)
150
100
0.3
30
200
10
DC resistive load
0.1
10
250
30
AC resistive load
0.5
G
6
K
Maximum coil voltage (%)
●Durability
Durability (x104 operations)
Switching current (A)
●Maximum Switching Capacity
100
90
max.
−
X
min.
80
70
60
50
40
90
Max. estimated value
80
70
max.
−
X
60
0.8
20
0.4
40
40
60
80
0
−60
100
−40
−20
0
20
Y
1,000
Energized
800
600 Deenergized
400
X
1,000
Z
1,000
200
200
400
1,000
Z'
800
1,000
Z'
100
Unit: m/s2
Sample: G6K-2G
Number of Relays: 10 pcs
Y'
Conditions: Shock is applied in ±X, ±Y, and ±Z
directions three times each with and
without energizing the Relays to check
the number of contact malfunctions.
●Contact Reliability Test *1, *2
G6K-2G (F/P), G6K-2G (F/P)-Y
max.
60
min.
Must operate voltage
max.
min.
Must release voltage
0
0.001
0.01
0.1
1
10
100
Operating frequency (x103 operations)
●Mutual Magnetic Interference
G6K-2G (F/P), G6K-2G (F/P)-Y
NC contact
min.
Sample
Change rate on the
basis of initial value (%)
NO contact
max.
max.
max.
min.
min.
Sample
Energized
4
40
60
1
10
100 1,000 10,000 100,000
Operating frequency (x103 operations)
Sample: G6K-2G
Number of Relays: 10 pcs
500 Test conditions: 1 A resistive load
at 30 VDC with an operation rate
of 50%
300 Switching frequency: 1,800
operations/h
80 100
NO contact
NC contact
max.
max.
min.
min.
Contact resistance
+30
+20
+10
0
−10
−20
−30
+30
+20
+10
0
−10
−20
−30
100
0.1
20
50
De-energized
10
0.001 0.01
0
100
Change rate on the
basis of initial value (%)
Contact resistance (mΩ)
Sample: G6K-2G
Number of Relays: 10 pcs
500 Test conditions: 10 μA resistive
load at 10 m VDC with an
operation rate of 50%
300 Switching frequency: 7,200
operations/h
30
−20
Ambient temperature (°C)
40
1,000
50
−40
1,000
Sample: G6K-2G
Number of Relays: 10 pcs
Test conditions: 1 A resistive load at 30 VDC
with an operation rate of 50%
80
Switching frequency: 1,800 operations/h
20
Y'
30
−60
80 100
1,000
X'
600
Shock directions
X
X'
Y
Z
60
●Electrical Durability (with Must Operate ●Electrical Durability
and Must Release Voltage) *1
(Contact Resistance) *1
G6K-2G (F/P), G6K-2G (F/P)-Y
G6K-2G (F/P), G6K-2G (F/P)-Y
On the basis of rated voltage (%)
●Shock Malfunction
40
Ambient temperature (°C)
Initial stage
30
10
0.001
0.01
0.1
1
10
100
Operating frequency (x103 operations)
●Mutual Magnetic Interference
G6K-2G (F/P), G6K-2G (F/P)-Y
Test
Sample
Average value
Initial stage
De-energized
Test
Sample
Average value
Must operate voltage
Must release voltage
Energized
Change rate on the
basis of initial value (%)
20
+30
+20
+10
0
−10
−20
−30
Change rate on the
basis of initial value (%)
0
Contact resistance (mΩ)
-20
Ambient temperature (°C)
*1.
*2.
50
Must operate voltage
Must release voltage
10
0
-40
min.
max.
−
X
min.
30
+30
+20
+10
0
−10
−20
−30
Initial stage
Test
Average value
Initial stage
Test
Average value
Must operate voltage
Must release voltage
The test was conducted at an ambient temperature of 23°C.
The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary
according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use.
G6K
Surface Mounting Relay
●External Magnetic Interference
G6K-2G (F/P), G6K-2G (F/P)-Y
S
N
+20
+10
0
−10
S
N
S
+20
+10
0
−10
−20
S
−30
−1,200
−800
−400
●High-frequency Characteristics
(Isolation) *1, *2
G6K-2G (F/P), G6K-2G (F/P)-Y
−30
−1,200
−800
−400
0
400
800 1,200
External magnetic field (A/m)
●High-frequency Characteristics
(Insertion Loss) ) *1, *2
G6K-2G (F/P), G6K-2G (F/P)-Y
(Average value (initial))
0
−10
20
30
Must operate voltage
Sample: G6K-2G
Must release voltage
Number of Relays: 10 pcs
−30
−1,200
−800
−400
0
400
800 1,200
External magnetic field (A/m)
●High-frequency Characteristics
(Return Loss) *1, *2
G6K-2G (F/P),G6K-2G (F/P)-Y
40
0
(Average value (initial))
Return loss (dB)
Sample: G6K-2G
10 Number of Relays: 10 pcs
N
+10
(Average value (initial))
Insertion loss (dB)
0
S
−20
Must operate voltage
Must release voltage
Sample: G6K-2G
Number of Relays: 10 pcs
0
400
800 1,200
External magnetic field (A/m)
N
+20
−20
Must operate voltage
Must release voltage
Sample: G6K-2G
Number of Relays: 10 pcs
Isolation (dB)
N
(Average value)
+30
0.1
0
10
1.4
Sample: G6K-2F-Y
Number of Relays: 5 pcs
1.35
20
1.3
30
0.2
V.SWR
N
Change rate on the basis of initial value (%)
Change rate on the basis of initial value (%)
S
(Average value)
+30
Change rate on the basis of initial value (%)
(Average value)
+30
1.25
Return loss
50
60
0.3
40
1.2
50
1.15
60
1.1
70
80
0.4
100
1
10
100
Frequency (MHz)
Must operate
voltage
Must release
voltage
Sample: G6K-2G
Number of Relays:
50 pcs
40
20
0
60
Must operate bounce time
Must release bounce time
40
0.5
1
1.5
2
2.5
3
0
0.5
1
Sample: G6K-2G
Number of Relays: 50 pcs
1.5
2
2.5
3
1.05
V.SWR
80
1
100
Frequency (MHz)
20
Time (ms)
*1.
*2.
10
●Must Operate and Must Release
Bounce Time Distribution *1
G6K-2G (F/P) , G6K-2G (F/P)-Y
Number of contacts
Number of contacts
●Must Operate and Must Release
Time Distribution *1
G6K-2G (F/P), G6K-2G (F/P)-Y
60
0.5
1
70
Sample: G6K-2G
Number of Relays: 10 pcs
10
1
100
Frequency (MHz)
●Vibration Resistance
G6K-2G (F/P), G6K-2G (F/P)-Y
Change rate on the basis of rated value (%)
90
10.0
5.0
Must operate voltage
0.0
Must release voltage
−5.0
−10.0
Initial
After test
Time (ms)
The tests were conducted at an ambient temperature of 23°C.
High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics including endurance in the actual machine
before use.
5
G
6
K
G6K
Surface Mounting Relay
■Dimensions (Unit: mm)
●Single-side Stable
G6K-2F
Mounting Dimensions (TOP VIEW)
Tolerance: ±0.1 mm
10±0.2
Terminal Arrangement/
Internal Connections
(TOP VIEW)
7.62
5.08
6.5±0.2
2.54
5.2±0.2
1.6
0.5±0.1
1.19
2.54
7.8
1.8
0.3
6
5
1
2
3
4
7
0.8
(1.19)
Orientation mark
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
G6K-2G
Note: Check carefully the coil
polarity of the Relay.
Mounting Dimensions (TOP VIEW)
Tolerance: ±0.1 mm
10±0.2
6.5±0.2
Terminal Arrangement/
Internal Connections
(TOP VIEW)
7.62
5.08
2.54
5.4±0.2
1.8
4.9
(2.54) (2.54)
0.8
(1.19)
2.54
6
5
1
2
3
4
Note: Check carefully the coil
polarity of the Relay.
PCB Mounting Holes (Bottom VIEW)
Tolerance: ±0.1 mm
6.5±0.2
7
Orientation mark
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
10±0.2
8
5.7
1.8
0.5
5.08
7.62
G G6K-2P
6
K
7
(2.54) (2.54)
5.08
7.62
0.5±0.1
1.19
2.54
8
Terminal Arrangement/
Internal Connections
(Bottom VIEW)
Eight, 0.85-dia. holes
Orientation mark
2.54
5
1
2
3
4
8
7
6
5
0.5
3.5
0.4±0.1
1.19
2.54
5.08
(2.54) (2.54)
R0.2
0.15
5.08
5.08
7.62
(0.71)
(1.19)
Note: Check carefully the coil
polarity of the Relay.
7.62
Note: Each value has a tolerance of ±0.3 mm.
G6K-2F-Y
Mounting Dimensions (TOP VIEW)
Tolerance: ±0.1 mm
6.5±0.2
10±0.2
3.2
Terminal Arrangement/
Internal Connections
(TOP VIEW)
7.6
5.4
5.2±0.2
1.6
0.5±0.1
1.2
3.2
7.8
1.8
0.3
0.8
(1.2)
G6K-2G-Y
5
1
2
3
4
Orientation mark
Note: Check carefully the coil
polarity of the Relay.
Mounting Dimensions (TOP VIEW)
Tolerance: ±0.1 mm
10±0.2
6.5±0.2
3.2
Terminal Arrangement/
Internal Connections
(TOP VIEW)
7.6
5.4
5.4±0.2
1.8
4.9
(2.2) (2.2)
1.8
0.5
5.4
7.6
0.8
(1.2)
G6K-2P-Y
6.5±0.2
3.2
5
7.6
5.4
7
6
5
1
2
3
4
Orientation mark
Note: Check carefully the coil
polarity of the Relay.
PCB Mounting Holes (BOTTOM VIEW)
Tolerance: ±0.1 mm
10±0.2
8
5.7
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
Eight, 0.85-dia. holes
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Orientation mark
1
2
3
4
8
7
6
5
0.5
0.4±0.1
1.2
3.2
5.08
(2.2) (2.2)
5.4
7.6
R0.2
0.15
5.08
(1.2)
Note: Each value has a tolerance of ±0.3 mm.
6
6
7
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
3.5
7
(2.2) (2.2)
5.4
7.6
0.5±0.1
1.2
3.2
8
(0.71)
Note: Check carefully the coil
polarity of the Relay.
G6K
Surface Mounting Relay
●Single-winding Latching
G6KU-2F-Y
Mounting Dimensions (TOP VIEW)
Tolerance: ±0.1 mm
6.5±0.2
10±0.2
3.2
Terminal Arrangement/
Internal Connections
(TOP VIEW)
7.6
5.4
8
5.2±0.2
1.6
0.5±0.1
1.2
3.2
7.8
1.8
0.3
7
7
6
5
2
3
4
SR
(2.2) (2.2)
5.4
7.6
1
0.8
(1.2)
Orientation mark
Note: Check carefully the coil
polarity of the Relay.
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
G6KU-2G-Y
Mounting Dimensions (TOP VIEW)
Tolerance: ±0.1 mm
10±0.2
6.5±0.2
3.2
Terminal Arrangement/
Internal Connections
(TOP VIEW)
7.6
5.4
8
5.4±0.2
1.8
0.5±0.1
1.2
3.2
4.9
(2.2) (2.2)
1.8
0.5
5.4
7.6
1
3.2
5
7.6
5.4
3
4
Eight, 0.85-dia. holes
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Orientation mark
1
3.5
2
Orientation mark
PCB Mounting Holes (BOTTOM VIEW)
Tolerance: ±0.1 mm
6.5±0.2
5
Note: Check carefully the coil
polarity of the Relay.
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
10±0.2
6
SR
5.7
0.8
(1.2)
G6KU-2P-Y
7
2
3
4
7
6
5
0.5
0.4±0.1
1.2
3.2
SR
5.08
(2.2) (2.2)
5.4
7.6
R0.2
0.15
5.08
(1.2)
Note: Each value has a tolerance of ±0.3 mm.
(0.71)
8
Note: Check carefully the coil
polarity of the Relay.
7
G
6
K
G6K
Surface Mounting Relay
■Tube Packing and Tape Packing
Surface mounting terminal (SMT) standard models are shipped in moisture-proof package, and PCB terminal standard types do not
require moisture proof packaging and therefore shipped in non-moisture-proof package.
Please refer to "Correct Use" for handling after opening moisture-proof packaging for Surface mounting terminal (SMT) models.
(1) Tube Packing
2. Reel Dimensions
• Relays in tube packing are arranged so that the orientation
mark of each Relay in on the left side. Fifty Relays are packed
on one tube.
Be sure not to make mistakes in Relay orientation when
mounting the Relay to the PCB.
Stopper
(gray)
17.5±1.0
21.5±1.0
2±0.5
13±0.2
21±0.5
80
330
Stopper
(green)
Orientation of Relays
R1
3. Carrier Tape Dimensions
G6K-2F, G6K-2F-Y, G6KU-2F-Y
Tube length: 520 mm (stopper not included)
No. of Relays per tube: 50 pcs
5.6±0.1
(2) Tape Packing (Surface Mounting Terminal Models)
• When ordering Relays in tape packing, add the prefix “-TR” to
the model number, otherwise the Relays in tube packing will
be provided.
Relays per Reel: 900 pcs
G
6
Minimum packing unit: 2 reels (1,800 pcs)
K
1. Direction of Relay Insertion
0.4±0.05
10.35
12±0.1
8.6
G6K-2G, G6K-2G-Y, G6KU-2G-Y
4±0.1
2±0.1
+0.1
1.5−0
Orientation mark
0.4±0.05
5.8±0.1
1.75±0.1
R0.3 max.
Pulling
direction
Carrier tape
1.75±0.1
7.5±0.1
16±0.1
Pulling direction
Top tape
(cover tape)
4±0.1
2±0.1
1.5+0.1
−0
7.5±0.1
16±0.1
10.6
10.6±0.1
Embossed
tape
12±0.1
3° max.
6.9
■Recommended Soldering Method
●IRS Method (for Surface-mounting Terminal Relays)
Temperature (°C)
(1) IRS Method (Mounting Solder: Lead)
Soldering
220 to 245
• The thickness of cream solder to be applied should be within a
range between 150 and 200 μm on OMRON’s recommended
PCB pattern.
• In order to perform correct soldering, it is recommended that
the correct soldering conditions be maintained as shown
below on the left side.
Correct Soldering
180 to 200
Incorrect Soldering
Relay
Terminal
Preheating
150
Land
Heel fillet
is formed
90 to 120
20 to 30
Time (s)
(The temperature profile indicates the temperature on the circuit board.)
Temperature (°C)
(2) IRS Method (Mounting Solder: Lead-free)
Uppwe surface of case
(peak): 255°C max.
Soldering
250 max.
230
180
150
Preheating
Relay terminal
section
120 max.
30 max.
Time (s)
(The temperature profile indicates the temperature on the PCB.)
8
PCB
Solder
Insufficient amount
of solder
Excessive amount
of solder
Visually check that the Relay is properly soldered.
G6K
Surface Mounting Relay
■Approved Standards
UL recognized:
CSA certified:
BSI (EN62368-1) (File No.VC689955)
UL1950 (File No. E41515)
C22.2 No. 950 (File No. LR31928)
Contact
form
Coil rating
Contact rating
Number of
test
operations
DPDT
(2c)
G6K-2G(F/P): 3 to 24 VDC
G6K(U)-2G(F/P)-Y: 3 to 24 VDC
2 A, 30 VDC at 40°C
0.5 A, 60 VDC at 40°C
0.3 A, 125 VAC at 40°C
6,000
Contact form
Isolation category
Voltage
DPDT (2c)
Basic Insulation
125 VAC
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Long-term Continuously ON Contacts
• Using the Relay in a circuit where the Relay will be ON
continuously for long periods (without switching) can lead to
unstable contacts because the heat generated by the coil itself
will affect the insulation, causing a film to develop on the
contact surfaces. We recommend using a latching relay
(magnetic-holding relay) in this kind of circuit. If a single-side
stable model must be used in this kind of circuit, we
recommend using a fail-safe circuit design that provides
protection against contact failure or coil burnout.
●Relay Handling
• Use the Relay as soon as possible after opening the
moistureproof package. (As a guideline, use the Relay within
one week at 30°C or less and 60% RH or less.) If the Relay is
left for a long time after opening the moisture-proof package,
the appearance may suffer and seal failure may occur after the
solder mounting process. To store the Relay after opening the
moisture-proof package, place it into the original package and
sealed the package with adhesive tape.
• When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep
the solvent temperature to less than 40°C. Do not put the
Relay in a cold cleaning bath immediately after soldering.
●Claw Securing Force During Automatic Mounting
• During automatic insertion of Relays, make sure to set the
securing force of each claw to the following so that the Relays
characteristics will be maintained.
C
A
B
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
●Environmental Conditions During Operation, Storage,
and Transportation
●Maximum Allowable Voltage
• The maximum allowable voltage of the coil can be obtained
from the coil temperature increase and the heat-resisting
temperature of coil insulating sheath material. (Exceeding the
heat-resisting temperature may result in burning or
short-circuiting.) The maximum allowable voltage also involves
important restrictions which include the following:
• Must not cause thermal changes in or deterioration of the
insulating material.
• Must not cause damage to other control devices.
• Must not cause any harmful effect on people.
• Must not cause fire.
Therefore, be sure to use the maximum allowable voltage
beyond the value specified in the catalog.
• As a rule, the rated voltage must be applied to the coil. A
voltage exceeding the rated value, however, can be applied to
the coil provided that the voltage is less than the maximum
allowable voltage. It must be noted that continuous voltage
application to the coil will cause a coil temperature increase
thus affecting characteristics such as electrical life and
resulting in the deterioration of coil insulation.
●Coating
• The Relay mounted on the PCB may be coated or washed but
do not apply silicone coating or detergent containing silicone,
otherwise the silicone coating or detergent may remain on the
surface of the Relay.
●PCB Mounting
• If two or more Relays are closely mounted with the long sides
of the Relays facing each other and soldering is performed
with infrared radiation, the solder may not be properly exposed
to the infrared rays. Be sure to keep the proper distance
between adjacent Relays as shown below.
G6K-2G
• Protect the Relay from direct sunlight and keep the Relay
under normal temperature, humidity, and pressure.
2 mm min.
●Latching Relay Mounting
• Make sure that the vibration or shock that is generated from
other devices, such as relays in operation, on the same panel
and imposed on the Latching Relay does not exceed the rated
value, otherwise the Latching Relay that has been set may be
reset or vice versa. The Latching Relay is reset before
shipping. If excessive vibration or shock is imposed, however,
the Latching Relay may be set accidentally. Be sure to apply a
reset signal before use.
G6K-2F
2.7 mm min.
• Two or more Relays may be closely mounted with the short
sides of the Relays facing each other.
9
G
6
K
G6K
Surface Mounting Relay
G
6
K
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
10
Contact: www.omron.com/ecb
Cat. No. K106-E1-11
0118(0207)(O)